




SLF8806 Dual Wavelength Fluorescence LED Light Source
LED No.: Two different wavelength combination
Lifespan: 30000H
Power supply: AC100-240V
Size: 116 * 108mm
Weight: Net 0.96KG
Share:
What is SLF8806 Series Inspection Lamp?
During the practical fluorescence excitation service, the protein excitation test can be completed under multiple wavelength, at least 2 different wavelength.
We developed a series dual wavelength excitation light source. Adding our professional SL8806 excitation light source adapter, without destroying the existing stereo microscope, you can perform the protein excitation observation test.
Parameter of SLF8806 Series Inspection Lamp
| Model | SLF8806-UB | SLF8804-BG | Remark |
|---|---|---|---|
| LED No. and specification | 3pcs 365NM and 3pcs 455NM LED | 3pcs 455NM and 3pcs 525NM LED | Customization according to customer demand |
| 365NM, 395NM, 455NM, 525NM, 595NM, 625NM, 6000K. Any two wavelength integration workable | |||
| Illuminance(30CM) | 28600uw/cm2-365NM 13500LX-455NM | 13500LX-455NM 40000LX-525NM | |
| Irradiated area(MM) | ○220MM—365NM ○180MM—455NM | ○180MM—455NM ○220MM—525NM | |
| Switch | The switch on head controls the 2 wavelengths. Dimmer switch | ||
| Lifespan | 30000H | ||
| Power supply | Dimmer (input 110-240V, Output ①-24V, 2A) Stepless dimming | ||
| Size and net weight | ABS+Aluminum alloy, size: 116*108mm180 * 190 * 106mm; Net: 0.68KG | ||
Why Choose/Features
1. The SLF8806 dual wavelength fluorescence excitation light source adapter can provide more complete solution for the existing microscope system. It can adapt (not convert) to any stereo microscope.
2. SLF8806 is with dual excitation wavelength. It can cover all the demand during the excitation service, providing more selection and solution for customers.
3. Stepless dimming function, the intensity of inspection lamp can be adjusted according to the test demand.
Specifications
Dual wavelength excitation light source SLF8806, easy to carry.
SLF800 adapter ring for microscope, suitable for any stereoscope and filter.
Light modulator: a customize-design dimmer, can be adjust the brightness of excitation light source, from 0-100%.
Observation Filter: Usually 3 different filter for your selection (SLF400-UV; SLF500-blue light; SLF600-green light)
- UV: excitation wavelength 330nm~400nm, emission wavelength 425nm
- Violet: excitation wavelength 395nm~415nm, emission wavelength 455nm
- Blue: Excitation wavelength 420nm~485nm, emission wavelength 515nm
- Green: Excitation wavelength 460nm~550nm, emission wavelength 590nm
Abbreviation
SLF-8806XX
U: 365NM ultraviolet ----V: 395NM violet---B: 455NM blue light---G: 525NM green light---A: 595NM amber light---R: 625NM red light
Application
- Fluorescence Microscopy
- Cell Structure Analysis
- Molecular Biology Research
- Protein & DNA Analysis
- Laboratory Sample Observation